
Language | English |
Pages | 158 |
Size | 1.53 Mb |
TABLE OF CONTENTS
Agilent 1000 Series Oscilloscopes—At a Glance 3
In This Book 4
Figures 13
Tables 15
1 Getting Started 17
Step 1. Inspect the package contents 18
Step 2. Turn on the oscilloscope 19
Step 3. Load the default oscilloscope setup 20
Step 4. Input a waveform 21
Step 5. Use Auto-Scale 22
Step 6. Compensate probes 24
Low Frequency Compensation 24
High Frequency Compensation 25
Step 7. Become familiar with the Front Panel Controls 26
Front Panel Overlays for Different Languages 27
Using the Oscilloscope Softkey Menus 28
Step 8. Become familiar with the oscilloscope display 30
Step 9. Use the Run Control keys 31
Step 10. Access the built-in help 32
6 Agilent 1000 Series Oscilloscopes User’s Guide
Securing the Oscilloscope 33
2 Displaying Data 35
Using the Horizontal Controls 36
To adjust the horizontal scale 37
To adjust the horizontal position 38
To display the zoomed time base 39
To change the horizontal time base (Y-T, X-Y, or Roll) 40
To view the sample rate 42
Using the Vertical Controls 43
To turn waveforms on or off (channel, math, or reference) 43
To adjust the vertical scale 44
To adjust the vertical position 44
To specify channel coupling 45
To specify a bandwidth limit 47
To specify the probe attenuation 48
To use a digital filter 49
To change the Volts/Div control sensitivity 50
To invert a waveform 50
To specify the channel units 52
Using Math Function Waveforms 53
To add, subtract, or multiply waveforms 54
To display the frequency domain using FFT 54
Using Reference Waveforms 57
To save a reference waveform 57
To export or import reference waveforms 57
To return the reference waveform to its default scale 58
Agilent 1000 Series Oscilloscopes User’s Guide 7
Changing the Display Settings 59
To display waveforms as vectors or dots 59
To clear the display 60
To set waveform persistence 60
To adjust waveform intensity 60
To display graded waveform intensity 61
To change the grid 61
To change the menu display time 62
To adjust the grid brightness 62
To invert screen colors 62
To select screen persistence 63
3 Capturing Data 65
Overview of Sampling 66
Oscilloscope Bandwidth and Sample Rate 67
Oscilloscope Rise Time 69
Oscilloscope Bandwidth Required 70
Real-Time Sampling 71
Memory Depth and Sample Rate 72
Choosing the Acquisition Mode 73
To select the Normal acquisition mode 73
To select the Average acquisition mode 74
To select the Peak Detect acquisition mode 75
To turn OFF/ON sine(x)/x interpolation 77
Recording/Playing-back Waveforms 78
To record waveforms 78
To play-back waveforms 79
To store recorded waveforms 81
8 Agilent 1000 Series Oscilloscopes User’s Guide
Adjusting the Trigger Level 83
To adjust the trigger level 83
To force a trigger 84
To set up edge triggers 85
To set up pulse width triggers 86
To set up video triggers 87
To set up pattern triggers 90
To set up alternate triggers 91
Setting Other Trigger Parameters 92
To set the trigger sweep 92
To set the trigger coupling 92
To set the trigger high-frequency reject coupling 93
To change the trigger sensitivity 94
To specify a trigger holdoff 95
Using the External Trigger Input 96
4 Making Measurements 97
Displaying Automatic Measurements 98
To display an automatic measurement 98
To clear automatic measurements from the display 99
To display or hide all automatic measurements 99
To select channels for delay/phase measurements 99
Agilent 1000 Series Oscilloscopes User’s Guide 9
Voltage Measurements 100
Vmax (Maximum Voltage) 100
Vmin (Minimum Voltage) 101
Vpp (Peak-to-Peak Voltage) 101
Vtop (Top Voltage) 101
Vbase (Base Voltage) 101
Vamp (Amplitude Voltage = Vtop - Vbase) 101
Vavg (Average Voltage) 101
Vrms (Root-Mean-Square Voltage) 102
Overshoot 102
Preshoot 102
Time Measurements 103
Period 103
Frequency 104
Rise Time 104
Fall Time 104
Positive Pulse Width 105
Negative Pulse Width 105
Positive Duty Cycle 105
Negative Duty Cycle 105
Delay Between Rising Edges 106
Delay Between Falling Edges 106
Phase Between Rising Edges 107
Phase Between Falling Edges 107
Counter (Frequency) 108
Making Cursor Measurements 109
To use manually adjustable cursors 110
To use tracking cross-hair cursors 111
To display cursors for automatic measurements 112
10 Agilent 1000 Series Oscilloscopes User’s Guide
5 Saving, Recalling, and Printing Data 113
Saving and Recalling Data 114
To save and recall waveforms 114
To save and recall oscilloscope setups 115
To save screens to BMP or PNG format files 116
To save data to CSV format files 117
Using the Disk Manager 118
To switch between files, path, and directory panes 119
To navigate the directory hierarchy 119
To create new folders 119
To edit folder/file names 120
To delete folders 121
To rename folders 121
To delete files 121
To recall files 122
To rename files 122
To display disk information 122
Printing Screens 123
To choose a PictBridge printer 124
To print with inverted screen colors 125
To choose color or grayscale printing 125
To copy a screen to the printer 126
6 Oscilloscope Utility Settings 127
Displaying System Information 128
Turning Sound ON or OFF 128
Setting and Displaying the Date and Time 129
Setting the Language (Menu and Help) 130
Agilent 1000 Series Oscilloscopes User’s Guide 11
Performing Mask Tests 131
To enable/disable mask tests 131
To select the source channel for mask tests 131
To run/stop a mask test 132
To turn on/off the mask test message display 132
To set the mask test output condition 133
To stop a mask test on the output condition 133
To set up masks 133
Setting Preferences 136
To set up the screen saver 136
To select the vertical scale reference level 136
To select the USB device port function 137
Running Self-Calibration 138
7 Specifications and Characteristics 139
Environmental Conditions 140
Overvoltage Category 140
Pollution Degree 140
Pollution Degree Definitions 140
Measurement Category 141
Measurement Category Definitions 141
Transient Withstand Capability 141
Specifications 142
Characteristics 143
ASafety Notices151
Warnings 151
Safety Symbols 152
12 Agilent 1000 Series Oscilloscopes User’s Guide
Contents
Index 153
Click on image to free download Manual and Book in PDF formats
Agilent 1000 Series Oscilloscopes—At a Glance 3
In This Book 4
Figures 13
Tables 15
1 Getting Started 17
Step 1. Inspect the package contents 18
Step 2. Turn on the oscilloscope 19
Step 3. Load the default oscilloscope setup 20
Step 4. Input a waveform 21
Step 5. Use Auto-Scale 22
Step 6. Compensate probes 24
Low Frequency Compensation 24
High Frequency Compensation 25
Step 7. Become familiar with the Front Panel Controls 26
Front Panel Overlays for Different Languages 27
Using the Oscilloscope Softkey Menus 28
Step 8. Become familiar with the oscilloscope display 30
Step 9. Use the Run Control keys 31
Step 10. Access the built-in help 32
6 Agilent 1000 Series Oscilloscopes User’s Guide
Securing the Oscilloscope 33
2 Displaying Data 35
Using the Horizontal Controls 36
To adjust the horizontal scale 37
To adjust the horizontal position 38
To display the zoomed time base 39
To change the horizontal time base (Y-T, X-Y, or Roll) 40
To view the sample rate 42
Using the Vertical Controls 43
To turn waveforms on or off (channel, math, or reference) 43
To adjust the vertical scale 44
To adjust the vertical position 44
To specify channel coupling 45
To specify a bandwidth limit 47
To specify the probe attenuation 48
To use a digital filter 49
To change the Volts/Div control sensitivity 50
To invert a waveform 50
To specify the channel units 52
Using Math Function Waveforms 53
To add, subtract, or multiply waveforms 54
To display the frequency domain using FFT 54
Using Reference Waveforms 57
To save a reference waveform 57
To export or import reference waveforms 57
To return the reference waveform to its default scale 58
Agilent 1000 Series Oscilloscopes User’s Guide 7
Changing the Display Settings 59
To display waveforms as vectors or dots 59
To clear the display 60
To set waveform persistence 60
To adjust waveform intensity 60
To display graded waveform intensity 61
To change the grid 61
To change the menu display time 62
To adjust the grid brightness 62
To invert screen colors 62
To select screen persistence 63
3 Capturing Data 65
Overview of Sampling 66
Oscilloscope Bandwidth and Sample Rate 67
Oscilloscope Rise Time 69
Oscilloscope Bandwidth Required 70
Real-Time Sampling 71
Memory Depth and Sample Rate 72
Choosing the Acquisition Mode 73
To select the Normal acquisition mode 73
To select the Average acquisition mode 74
To select the Peak Detect acquisition mode 75
To turn OFF/ON sine(x)/x interpolation 77
Recording/Playing-back Waveforms 78
To record waveforms 78
To play-back waveforms 79
To store recorded waveforms 81
8 Agilent 1000 Series Oscilloscopes User’s Guide
Adjusting the Trigger Level 83
To adjust the trigger level 83
To force a trigger 84
To set up edge triggers 85
To set up pulse width triggers 86
To set up video triggers 87
To set up pattern triggers 90
To set up alternate triggers 91
Setting Other Trigger Parameters 92
To set the trigger sweep 92
To set the trigger coupling 92
To set the trigger high-frequency reject coupling 93
To change the trigger sensitivity 94
To specify a trigger holdoff 95
Using the External Trigger Input 96
4 Making Measurements 97
Displaying Automatic Measurements 98
To display an automatic measurement 98
To clear automatic measurements from the display 99
To display or hide all automatic measurements 99
To select channels for delay/phase measurements 99
Agilent 1000 Series Oscilloscopes User’s Guide 9
Voltage Measurements 100
Vmax (Maximum Voltage) 100
Vmin (Minimum Voltage) 101
Vpp (Peak-to-Peak Voltage) 101
Vtop (Top Voltage) 101
Vbase (Base Voltage) 101
Vamp (Amplitude Voltage = Vtop - Vbase) 101
Vavg (Average Voltage) 101
Vrms (Root-Mean-Square Voltage) 102
Overshoot 102
Preshoot 102
Time Measurements 103
Period 103
Frequency 104
Rise Time 104
Fall Time 104
Positive Pulse Width 105
Negative Pulse Width 105
Positive Duty Cycle 105
Negative Duty Cycle 105
Delay Between Rising Edges 106
Delay Between Falling Edges 106
Phase Between Rising Edges 107
Phase Between Falling Edges 107
Counter (Frequency) 108
Making Cursor Measurements 109
To use manually adjustable cursors 110
To use tracking cross-hair cursors 111
To display cursors for automatic measurements 112
10 Agilent 1000 Series Oscilloscopes User’s Guide
5 Saving, Recalling, and Printing Data 113
Saving and Recalling Data 114
To save and recall waveforms 114
To save and recall oscilloscope setups 115
To save screens to BMP or PNG format files 116
To save data to CSV format files 117
Using the Disk Manager 118
To switch between files, path, and directory panes 119
To navigate the directory hierarchy 119
To create new folders 119
To edit folder/file names 120
To delete folders 121
To rename folders 121
To delete files 121
To recall files 122
To rename files 122
To display disk information 122
Printing Screens 123
To choose a PictBridge printer 124
To print with inverted screen colors 125
To choose color or grayscale printing 125
To copy a screen to the printer 126
6 Oscilloscope Utility Settings 127
Displaying System Information 128
Turning Sound ON or OFF 128
Setting and Displaying the Date and Time 129
Setting the Language (Menu and Help) 130
Agilent 1000 Series Oscilloscopes User’s Guide 11
Performing Mask Tests 131
To enable/disable mask tests 131
To select the source channel for mask tests 131
To run/stop a mask test 132
To turn on/off the mask test message display 132
To set the mask test output condition 133
To stop a mask test on the output condition 133
To set up masks 133
Setting Preferences 136
To set up the screen saver 136
To select the vertical scale reference level 136
To select the USB device port function 137
Running Self-Calibration 138
7 Specifications and Characteristics 139
Environmental Conditions 140
Overvoltage Category 140
Pollution Degree 140
Pollution Degree Definitions 140
Measurement Category 141
Measurement Category Definitions 141
Transient Withstand Capability 141
Specifications 142
Characteristics 143
ASafety Notices151
Warnings 151
Safety Symbols 152
12 Agilent 1000 Series Oscilloscopes User’s Guide
Contents
Index 153
Click on image to free download Manual and Book in PDF formats