Language | English |
Pages | 352 |
Size | 6.27 Mb |
TABLE OF CONTENTS
1 Getting Started
Inspect the Package Contents 21
Install the Optional LAN/VGA or GPIB Module 24
Tilt the Oscilloscope for Easy Viewing 24
Power-On the Oscilloscope 25
Connect Probes to the Oscilloscope 26
Maximum input voltage at analog inputs 26
Do not float the oscilloscope chassis 26
Input a Waveform 27
Recall the Default Oscilloscope Setup 27
Use Auto Scale 28
Compensate Passive Probes 29
Learn the Front Panel Controls and Connectors 30
Front Panel Overlays for Different Languages 37
Learn the Rear Panel Connectors 39
Learn the Oscilloscope Display 41
Access the Built-In Quick Help 42
8 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
2 Horizontal Controls
To adjust the horizontal (time/div) scale 46
To adjust the horizontal delay (position) 47
Panning and Zooming Singleor Stopped Acquisitions 48
To change the horizontal time mode (Normal, XY, or Roll) 49
XY Time Mode 50
To display the zoomed time base 52
To change the horizontal scale knob's coarse/fine adjustment
setting 54
To position the time reference (left, center, right) 54
Searching for Events 55
To set up searches 55
Navigating the Time Base 56
To navigate time 56
To navigate search events 56
To navigate segments 57
3 Vertical Controls
To turn waveforms on or off (channel or math) 60
To adjust the vertical scale 61
To adjust the vertical position 61
To specify channel coupling 61
To specify bandwidth limiting 62
To change the vertical scale knob's coarse/fine adjustment
setting 62
To invert a waveform 63
Setting Analog Channel Probe Options 63
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 9
To specify the channel units 64
To specify the probe attenuation 64
To specify the probe skew 65
4Math Waveforms
To display math waveforms 67
To perform a transform function on an arithmetic operation 68
To adjust the math waveform scale and offset 69
Units for Math Waveforms 69
Math Operators 70
Add or Subtract 70
Multiply or Divide 71
Math Transforms 72
FFT Measurement 72
5 Reference Waveforms
To save a waveform to a reference waveform location 81
To display a reference waveform 82
To scale and position reference waveforms 83
To adjust reference waveform skew 83
To display reference waveform information 84
To save/recall reference waveform files to/from a USB storage
device 84
6 Digital Channels
To connect the digital probes to the device under test 86
Probe cable for digital channels 86
Acquiring waveforms using the digital channels 89
10 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
To display digital channels using AutoScale 89
Interpreting the digital waveform display 90
To change the displayed size of the digital channels 91
To switch a single channel on or off 92
To switch all digital channels on or off 92
To switch groups of channels on or off 92
To change the logic threshold for digital channels 92
To reposition a digital channel 93
To display digital channels as a bus 94
Digital channel signal fidelity: Probe impedance and
grounding 97
Input Impedance 98
Probe Grounding 100
Best Probing Practices 102
To replace digital probe leads 102
7 Serial Decode
Serial Decode Options 105
Lister 106
Searching Lister Data 108
8 Display Settings
To adjust waveform intensity 111
To set or clear persistence 113
To clear the display 114
To select the grid type 114
To adjust the grid intensity 115
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 11
To freeze the display 115
9Labels
To turn the label display on or off 117
To assign a predefined label to a channel 118
To define a new label 119
To load a list of labels from a text file you create 120
To reset the label libraryto the factory default 121
10 Triggers
Adjusting the Trigger Level 124
Forcing a Trigger 125
Edge Trigger 125
Pattern Trigger 128
Hex Bus Pattern Trigger 130
Pulse Width Trigger 131
Video Trigger 133
To trigger on a specific line of video 137
To trigger on all sync pulses 138
To trigger on a specific field of the video signal 139
To trigger on all fields of the video signal 140
To trigger on odd or even fields 141
Serial Trigger 143
11 Trigger Mode/Coupling
To select the Auto or Normal trigger mode 146
To select the trigger coupling 148
To enable or disable trigger noise rejection 149
12 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
To enable or disable trigger HF Reject 149
To set the trigger holdoff 150
External Trigger Input 150
Maximum voltage at oscilloscope external trigger input 151
12 Acquisition Control
Running, Stopping, and Making Single Acquisitions (Run
Control) 153
Overview of Sampling 155
Sampling Theory 155
Aliasing 155
Oscilloscope Bandwidth and Sample Rate 156
Oscilloscope Rise Time 157
Oscilloscope Bandwidth Required 158
Memory Depth and Sample Rate 159
Selecting the Acquisition Mode 159
Normal Acquisition Mode 160
Peak Detect Acquisition Mode 160
Averaging Acquisition Mode 163
High Resolution Acquisition Mode 165
Acquiring to Segmented Memory 165
Navigating Segments 167
Infinite Persistence with Segmented Memory 167
Segmented Memory Re-Arm Time 168
Saving Data from Segmented Memory 168
13 Cursors
To make cursor measurements 170
Cursor Examples 173
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 13
14 Measurements
To make automatic measurements 180
Measurements Summary 181
Snapshot All 183
Voltage Measurements 183
Peak-Peak 184
Maximum 184
Minimum 184
Amplitude 184
Top 185
Base 186
Overshoot 186
Preshoot 187
Average 188
DC RMS 188
AC RMS 189
Time Measurements 191
Period 191
Frequency 192
+ Width 193
– Width 193
Duty Cycle 193
Rise Time 193
Fall Time 193
Delay 194
Phase 195
Measurement Thresholds 196
Measurement Window with Zoom Display 198
15 Mask Testing
To create a mask from a "golden" waveform (Automask) 199
14 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
Mask Test Setup Options 201
Mask Statistics 204
To manually modify a mask file 205
Building a Mask File 208
How is mask testing done? 210
16 Digital Voltmeter
17 Waveform Generator
To select generated waveform types and settings 215
To output the waveform generator sync pulse 218
To specify the expected output load 219
To use waveform generator logic presets 219
To add noise to the waveform generator output 220
To add modulation to the waveform generator output 220
To set up Amplitude Modulation (AM) 221
To set up Frequency Modulation (FM) 223
To set up Frequency-Shift Keying Modulation (FSK) 224
To restore waveform generator defaults 225
18 Save/Recall (Setups, Screens, Data)
Saving Setups, Screen Images, or Data 227
To save setup files 229
To save BMP or PNG image files 229
To save CSV, ASCII XY, or BIN data files 230
Length Control 231
To save Lister data files 232
To save reference waveform files to a USB storage device 233
To save masks 233
To navigate storage locations 234
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 15
To enter file names 234
Recalling Setups, Masks, or Reference Waveforms 235
To recall setup files 235
To recall mask files 236
To recall reference waveformfiles from a USB storage
device 236
Recalling Default Setups 237
Performing a Secure Erase 237
19 Print (Screens)
To print the oscilloscope's display 239
To set up network printer connections 240
To specify the print options 242
To specify the palette option 243
20 Utility Settings
I/O Interface Settings 245
Setting up the Oscilloscope's LAN Connection 246
To establish a LAN connection 247
Stand-alone (Point-to-Point) Connection to a PC 248
File Explorer 249
Setting Oscilloscope Preferences 251
To choose "expand about" center or ground 251
To disable/enable transparent backgrounds 252
To load the default label library 252
To set up the screen saver 252
To set AutoScale preferences 253
Setting the Oscilloscope's Clock 254
Setting the Rear Panel TRIG OUT Source 254
16 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
Performing Service Tasks 255
To perform user calibration 256
To perform hardware self test 258
To perform front panel self test 259
To display oscilloscope information 259
To display the user calibration status 259
To clean the oscilloscope 259
To check warranty and extended services status 260
To contact Agilent 260
To return the instrument 260
Configuring the [Quick Action] Key 261
Adding an Annotation 262
21 Web Interface
Accessing the Web Interface 266
Browser Web Control 267
Real Scope Remote Front Panel 268
Simple Remote Front Panel 269
Browser-Based Remote Front Panel 270
Remote Programming via the Web Interface 271
Remote Programming withAgilent IO Libraries 272
Save/Recall 273
Saving Files via the Web Interface 273
Recalling Files via the Web Interface 274
Get Image 275
Identification Function 276
Instrument Utilities 276
Setting a Password 277
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 17
22 Reference
Specifications and Characteristics 281
Measurement Category 281
Oscilloscope Measurement Category 282
Measurement Category Definitions 282
Transient Withstand Capability 283
Maximum input voltage at analog inputs 283
Maximum input voltage at digital channels 283
Environmental Conditions 283
Probes and Accessories 284
Passive Probes 284
Differential Probes 285
Current Probes 285
Accessories Available 286
Loading Licenses and Displaying License Information 287
Licensed Options Available 287
Other Options Available 288
Upgrading to an MSO 288
Software and Firmware Updates 289
Binary Data (.bin) Format 289
Binary Data in MATLAB 290
Binary Header Format 290
Example Program for Reading Binary Data 293
Examples of Binary Files 293
CSV and ASCII XY files 296
CSV and ASCII XY file structure 297
Minimum and Maximum Values in CSV Files 297
18 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
Acknowledgements 298
23 CAN/LIN Triggeringand Serial Decode
Setup for CAN Signals 299
CAN Triggering 301
CAN Serial Decode 303
Interpreting CAN Decode 304
CAN Totalizer 305
Interpreting CAN Lister Data 306
Searching for CAN Data in the Lister 307
Setup for LIN Signals 307
LIN Triggering 309
LIN Serial Decode 311
Interpreting LIN Decode 312
Interpreting LIN Lister Data 313
Searching for LIN Data in the Lister 314
24 I2C/SPI Triggering and Serial Decode
Setup for I2C Signals 315
I2C Triggering 316
I2C Serial Decode 320
Interpreting I2C Decode 321
Interpreting I2C Lister Data 322
Searching for I2C Data in the Lister 323
Setup for SPI Signals 324
SPI Triggering 327
SPI Serial Decode 329
Interpreting SPI Decode 331
Interpreting SPI Lister Data 332
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 19
Searching for SPI Data in the Lister 332
25 UART/RS232 Triggering and Serial Decode
Setup for UART/RS232 Signals 335
UART/RS232 Triggering 337
UART/RS232 Serial Decode 339
Interpreting UART/RS232 Decode 341
UART/RS232 Totalizer 342
Interpreting UART/RS232 Lister Data 343
Searching for UART/RS232 Data in the Lister 343
Index
Click on image to free download Manual and Book in PDF formats
1 Getting Started
Inspect the Package Contents 21
Install the Optional LAN/VGA or GPIB Module 24
Tilt the Oscilloscope for Easy Viewing 24
Power-On the Oscilloscope 25
Connect Probes to the Oscilloscope 26
Maximum input voltage at analog inputs 26
Do not float the oscilloscope chassis 26
Input a Waveform 27
Recall the Default Oscilloscope Setup 27
Use Auto Scale 28
Compensate Passive Probes 29
Learn the Front Panel Controls and Connectors 30
Front Panel Overlays for Different Languages 37
Learn the Rear Panel Connectors 39
Learn the Oscilloscope Display 41
Access the Built-In Quick Help 42
8 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
2 Horizontal Controls
To adjust the horizontal (time/div) scale 46
To adjust the horizontal delay (position) 47
Panning and Zooming Singleor Stopped Acquisitions 48
To change the horizontal time mode (Normal, XY, or Roll) 49
XY Time Mode 50
To display the zoomed time base 52
To change the horizontal scale knob's coarse/fine adjustment
setting 54
To position the time reference (left, center, right) 54
Searching for Events 55
To set up searches 55
Navigating the Time Base 56
To navigate time 56
To navigate search events 56
To navigate segments 57
3 Vertical Controls
To turn waveforms on or off (channel or math) 60
To adjust the vertical scale 61
To adjust the vertical position 61
To specify channel coupling 61
To specify bandwidth limiting 62
To change the vertical scale knob's coarse/fine adjustment
setting 62
To invert a waveform 63
Setting Analog Channel Probe Options 63
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 9
To specify the channel units 64
To specify the probe attenuation 64
To specify the probe skew 65
4Math Waveforms
To display math waveforms 67
To perform a transform function on an arithmetic operation 68
To adjust the math waveform scale and offset 69
Units for Math Waveforms 69
Math Operators 70
Add or Subtract 70
Multiply or Divide 71
Math Transforms 72
FFT Measurement 72
5 Reference Waveforms
To save a waveform to a reference waveform location 81
To display a reference waveform 82
To scale and position reference waveforms 83
To adjust reference waveform skew 83
To display reference waveform information 84
To save/recall reference waveform files to/from a USB storage
device 84
6 Digital Channels
To connect the digital probes to the device under test 86
Probe cable for digital channels 86
Acquiring waveforms using the digital channels 89
10 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
To display digital channels using AutoScale 89
Interpreting the digital waveform display 90
To change the displayed size of the digital channels 91
To switch a single channel on or off 92
To switch all digital channels on or off 92
To switch groups of channels on or off 92
To change the logic threshold for digital channels 92
To reposition a digital channel 93
To display digital channels as a bus 94
Digital channel signal fidelity: Probe impedance and
grounding 97
Input Impedance 98
Probe Grounding 100
Best Probing Practices 102
To replace digital probe leads 102
7 Serial Decode
Serial Decode Options 105
Lister 106
Searching Lister Data 108
8 Display Settings
To adjust waveform intensity 111
To set or clear persistence 113
To clear the display 114
To select the grid type 114
To adjust the grid intensity 115
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 11
To freeze the display 115
9Labels
To turn the label display on or off 117
To assign a predefined label to a channel 118
To define a new label 119
To load a list of labels from a text file you create 120
To reset the label libraryto the factory default 121
10 Triggers
Adjusting the Trigger Level 124
Forcing a Trigger 125
Edge Trigger 125
Pattern Trigger 128
Hex Bus Pattern Trigger 130
Pulse Width Trigger 131
Video Trigger 133
To trigger on a specific line of video 137
To trigger on all sync pulses 138
To trigger on a specific field of the video signal 139
To trigger on all fields of the video signal 140
To trigger on odd or even fields 141
Serial Trigger 143
11 Trigger Mode/Coupling
To select the Auto or Normal trigger mode 146
To select the trigger coupling 148
To enable or disable trigger noise rejection 149
12 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
To enable or disable trigger HF Reject 149
To set the trigger holdoff 150
External Trigger Input 150
Maximum voltage at oscilloscope external trigger input 151
12 Acquisition Control
Running, Stopping, and Making Single Acquisitions (Run
Control) 153
Overview of Sampling 155
Sampling Theory 155
Aliasing 155
Oscilloscope Bandwidth and Sample Rate 156
Oscilloscope Rise Time 157
Oscilloscope Bandwidth Required 158
Memory Depth and Sample Rate 159
Selecting the Acquisition Mode 159
Normal Acquisition Mode 160
Peak Detect Acquisition Mode 160
Averaging Acquisition Mode 163
High Resolution Acquisition Mode 165
Acquiring to Segmented Memory 165
Navigating Segments 167
Infinite Persistence with Segmented Memory 167
Segmented Memory Re-Arm Time 168
Saving Data from Segmented Memory 168
13 Cursors
To make cursor measurements 170
Cursor Examples 173
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 13
14 Measurements
To make automatic measurements 180
Measurements Summary 181
Snapshot All 183
Voltage Measurements 183
Peak-Peak 184
Maximum 184
Minimum 184
Amplitude 184
Top 185
Base 186
Overshoot 186
Preshoot 187
Average 188
DC RMS 188
AC RMS 189
Time Measurements 191
Period 191
Frequency 192
+ Width 193
– Width 193
Duty Cycle 193
Rise Time 193
Fall Time 193
Delay 194
Phase 195
Measurement Thresholds 196
Measurement Window with Zoom Display 198
15 Mask Testing
To create a mask from a "golden" waveform (Automask) 199
14 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
Mask Test Setup Options 201
Mask Statistics 204
To manually modify a mask file 205
Building a Mask File 208
How is mask testing done? 210
16 Digital Voltmeter
17 Waveform Generator
To select generated waveform types and settings 215
To output the waveform generator sync pulse 218
To specify the expected output load 219
To use waveform generator logic presets 219
To add noise to the waveform generator output 220
To add modulation to the waveform generator output 220
To set up Amplitude Modulation (AM) 221
To set up Frequency Modulation (FM) 223
To set up Frequency-Shift Keying Modulation (FSK) 224
To restore waveform generator defaults 225
18 Save/Recall (Setups, Screens, Data)
Saving Setups, Screen Images, or Data 227
To save setup files 229
To save BMP or PNG image files 229
To save CSV, ASCII XY, or BIN data files 230
Length Control 231
To save Lister data files 232
To save reference waveform files to a USB storage device 233
To save masks 233
To navigate storage locations 234
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 15
To enter file names 234
Recalling Setups, Masks, or Reference Waveforms 235
To recall setup files 235
To recall mask files 236
To recall reference waveformfiles from a USB storage
device 236
Recalling Default Setups 237
Performing a Secure Erase 237
19 Print (Screens)
To print the oscilloscope's display 239
To set up network printer connections 240
To specify the print options 242
To specify the palette option 243
20 Utility Settings
I/O Interface Settings 245
Setting up the Oscilloscope's LAN Connection 246
To establish a LAN connection 247
Stand-alone (Point-to-Point) Connection to a PC 248
File Explorer 249
Setting Oscilloscope Preferences 251
To choose "expand about" center or ground 251
To disable/enable transparent backgrounds 252
To load the default label library 252
To set up the screen saver 252
To set AutoScale preferences 253
Setting the Oscilloscope's Clock 254
Setting the Rear Panel TRIG OUT Source 254
16 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
Performing Service Tasks 255
To perform user calibration 256
To perform hardware self test 258
To perform front panel self test 259
To display oscilloscope information 259
To display the user calibration status 259
To clean the oscilloscope 259
To check warranty and extended services status 260
To contact Agilent 260
To return the instrument 260
Configuring the [Quick Action] Key 261
Adding an Annotation 262
21 Web Interface
Accessing the Web Interface 266
Browser Web Control 267
Real Scope Remote Front Panel 268
Simple Remote Front Panel 269
Browser-Based Remote Front Panel 270
Remote Programming via the Web Interface 271
Remote Programming withAgilent IO Libraries 272
Save/Recall 273
Saving Files via the Web Interface 273
Recalling Files via the Web Interface 274
Get Image 275
Identification Function 276
Instrument Utilities 276
Setting a Password 277
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 17
22 Reference
Specifications and Characteristics 281
Measurement Category 281
Oscilloscope Measurement Category 282
Measurement Category Definitions 282
Transient Withstand Capability 283
Maximum input voltage at analog inputs 283
Maximum input voltage at digital channels 283
Environmental Conditions 283
Probes and Accessories 284
Passive Probes 284
Differential Probes 285
Current Probes 285
Accessories Available 286
Loading Licenses and Displaying License Information 287
Licensed Options Available 287
Other Options Available 288
Upgrading to an MSO 288
Software and Firmware Updates 289
Binary Data (.bin) Format 289
Binary Data in MATLAB 290
Binary Header Format 290
Example Program for Reading Binary Data 293
Examples of Binary Files 293
CSV and ASCII XY files 296
CSV and ASCII XY file structure 297
Minimum and Maximum Values in CSV Files 297
18 Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
Acknowledgements 298
23 CAN/LIN Triggeringand Serial Decode
Setup for CAN Signals 299
CAN Triggering 301
CAN Serial Decode 303
Interpreting CAN Decode 304
CAN Totalizer 305
Interpreting CAN Lister Data 306
Searching for CAN Data in the Lister 307
Setup for LIN Signals 307
LIN Triggering 309
LIN Serial Decode 311
Interpreting LIN Decode 312
Interpreting LIN Lister Data 313
Searching for LIN Data in the Lister 314
24 I2C/SPI Triggering and Serial Decode
Setup for I2C Signals 315
I2C Triggering 316
I2C Serial Decode 320
Interpreting I2C Decode 321
Interpreting I2C Lister Data 322
Searching for I2C Data in the Lister 323
Setup for SPI Signals 324
SPI Triggering 327
SPI Serial Decode 329
Interpreting SPI Decode 331
Interpreting SPI Lister Data 332
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide 19
Searching for SPI Data in the Lister 332
25 UART/RS232 Triggering and Serial Decode
Setup for UART/RS232 Signals 335
UART/RS232 Triggering 337
UART/RS232 Serial Decode 339
Interpreting UART/RS232 Decode 341
UART/RS232 Totalizer 342
Interpreting UART/RS232 Lister Data 343
Searching for UART/RS232 Data in the Lister 343
Index